{"title":"Low Output","description":"\u003cp\u003eLow output usually traces to a degraded flash lamp, a damaged or contaminated optic in the beam path, a worn laser rod, or a fouled protective window. Work through the beam path in that order.\u003c\/p\u003e","products":[{"product_id":"candela-aperture-lens-18-mm","title":"Candela Aperture Lens 18 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle series handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to an 18 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927654007168,"sku":"CND-0077","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0077.jpg?v=1789840430"},{"product_id":"candela-aperture-lens-24-mm-type-1","title":"Candela Aperture Lens 24 mm (Type 1)","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle Pro series handpieces, 24 mm Type 1.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e\u003cp\u003eThree 24 mm lens types exist for this platform; confirm the fitted type against your slider before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927654465920,"sku":"CND-0078","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0078.jpg?v=1789840465"},{"product_id":"candela-aperture-lens-24-mm-type-2","title":"Candela Aperture Lens 24 mm (Type 2)","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle Pro series handpieces, 24 mm Type 2.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e\u003cp\u003eThree 24 mm lens types exist for this platform; confirm the fitted type against your slider before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927654990208,"sku":"CND-0079","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0079.jpg?v=1789839885"},{"product_id":"candela-aperture-lens-24-mm-type-3","title":"Candela Aperture Lens 24 mm (Type 3)","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle Pro series handpieces, 24 mm Type 3.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e\u003cp\u003eThree 24 mm lens types exist for this platform; confirm the fitted type against your slider before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927655645568,"sku":"CND-0080","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0080.jpg?v=1789839868"},{"product_id":"candela-beam-combiner","title":"Candela Beam Combiner","description":"\u003cp\u003e\u003cstrong\u003eBeam combiner for Candela Gentle Pro series systems.\u003c\/strong\u003e Dichroic optic that merges the 755 nm and 1064 nm paths into a single output line in dual wavelength configurations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Coating damage attenuates or misaligns one wavelength's path more than the other, so the two outputs drift apart and a single calibration can no longer hold both wavelengths at spec.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927656071552,"sku":"CND-0084","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0084.jpg?v=1789840508"},{"product_id":"candela-beam-splitter","title":"Candela Beam Splitter","description":"\u003cp\u003e\u003cstrong\u003eBeam splitter for Candela Gentle Pro series systems.\u003c\/strong\u003e Partially reflective optic that divides the beam between paths at a fixed ratio, feeding the system the sample it uses to monitor output energy.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Coating degradation shifts the split ratio, so the sampled energy and the delivered energy drift apart. The system calibrates to the sample, which means real output at the skin walks away from the displayed value.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927656333696,"sku":"CND-0085","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0085.jpg?v=1789840578"},{"product_id":"candela-flash-lamp","title":"Candela Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Candela Gentle series laser systems.\u003c\/strong\u003e Glass envelope with a xenon gas fill and ceramic end caps, mounted alongside the laser rod inside the water-cooled cavity. Each capacitor discharge fires the lamp, producing the intense broadband light pulse that pumps the rod and generates the treatment beam. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927659577728,"sku":"CND-0054","price":165.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0054.jpg?v=1789840379"},{"product_id":"candela-focus-lens","title":"Candela Focus Lens","description":"\u003cp\u003e\u003cstrong\u003eFocus lens for Candela Gentle Pro series systems.\u003c\/strong\u003e Precision element that converges the beam to its working focal point in the optical train, holding spot geometry and energy density at the design values.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage defocuses the beam at its target plane, spreading energy the system expects to be concentrated. Coupled energy drops, surrounding mounts absorb the difference as heat, and the delivered spot degrades.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927660396928,"sku":"CND-0086","price":60.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"candela-intermediate-lens","title":"Candela Intermediate Lens","description":"\u003cp\u003e\u003cstrong\u003eIntermediate lens for Candela Gentle Pro series systems.\u003c\/strong\u003e Relay element that keeps the beam collimated between stages of the optical train so the full aperture arrives at the next optic.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage lets the beam spread between stages, clipping energy at downstream apertures and softening the spot at the handpiece. Because the loss is distributed, it often reads as general low output rather than one failed optic.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927666196864,"sku":"CND-0087","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0087.jpg?v=1789840597"},{"product_id":"candela-laser-head-cavity","title":"Candela Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for Candela Gentle series systems.\u003c\/strong\u003e Reflective chamber that holds the flash lamp, laser rod, and coolant flow tubes in fixed alignment, focusing the lamp's pump light into the rod on every discharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rod and output falls below what calibration can recover. Damage compounds because the system drives the lamp harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927667048832,"sku":"CND-0033","price":990.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0033.jpg?v=1792157083"},{"product_id":"candela-turning-mirror","title":"Candela Turning Mirror","description":"\u003cp\u003e\u003cstrong\u003eTurning mirror for Candela Gentle Pro series systems.\u003c\/strong\u003e Coated mirror that folds the beam through the internal path at a fixed angle, keeping the line between rod and handpiece aligned within the housing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Coating burns and pitting scatter energy out of the folded path, cutting delivered fluence and heating the mount. Scatter also degrades beam shape by the time it reaches the handpiece, so losses show at the skin before they show on the bench.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927669801344,"sku":"CND-0088","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0088.jpg?v=1789840619"},{"product_id":"lutronic-clarity-aperture-lens-15-mm","title":"Lutronic Clarity Aperture Lens 15 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 15 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670129024,"sku":"CLR-0020","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-aperture-lens-18-mm","title":"Lutronic Clarity Aperture Lens 18 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 18 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670358400,"sku":"CLR-0021","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-aperture-lens-20-mm","title":"Lutronic Clarity Aperture Lens 20 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 20 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670587776,"sku":"CLR-0022","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-common-aperture-lens","title":"Lutronic Clarity Common Aperture Lens","description":"\u003cp\u003e\u003cstrong\u003eCommon aperture lens for the Lutronic Clarity platform.\u003c\/strong\u003e Shared element that sits in the beam path for every spot size configuration it serves, shaping output ahead of the size-specific optics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Because every configuration passes through it, surface damage drags output down across all the spot sizes it serves at once, and the loss tracks every setting equally rather than pointing at one size.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670751616,"sku":"CLR-0023","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-flash-lamp","title":"Lutronic Clarity Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Lutronic Clarity laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671144832,"sku":"CLR-0015","price":200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-focus-lens","title":"Lutronic Clarity Focus Lens","description":"\u003cp\u003e\u003cstrong\u003eFocus lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision element that converges the beam to its working focal point for treatment delivery, holding spot geometry and energy density at the design values.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage defocuses the beam at its target plane, spreading energy the system expects to be concentrated. Coupled energy drops, surrounding mounts absorb the difference as heat, and the delivered spot degrades.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671275904,"sku":"CLR-0024","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-ii-flash-lamp","title":"Lutronic Clarity II Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Lutronic Clarity II laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e\u003cp\u003eNot interchangeable with the original Clarity lamp; confirm the system version before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671439744,"sku":"CLR-0016","price":200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-protective-window","title":"Lutronic Clarity Protective Window","description":"\u003cp\u003e\u003cstrong\u003eDisposable protective window for the Lutronic Clarity handpiece.\u003c\/strong\u003e Flat optical window that sits in front of the internal lenses and takes the debris, gel, and hair contact of every treatment, so contamination lands on a replaceable part instead of the optics behind it. Sold per piece.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Debris burned onto the surface absorbs pulse energy, etching the glass and turning the window from a shield into an absorber. Left in place, a marked window scatters energy, distorts the spot, and passes heat damage down the optical train.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671996800,"sku":"CLR-0025","price":10.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-18-mm","title":"Cynosure Aperture Lens 18 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Cynosure Elite series handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 18 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672324480,"sku":"CYN-0050","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-20-mm","title":"Cynosure Aperture Lens 20 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Cynosure Elite+ handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 20 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672488320,"sku":"CYN-0051","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-22-mm","title":"Cynosure Aperture Lens 22 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Cynosure Elite+ handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 22 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672553856,"sku":"CYN-0052","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-24-mm","title":"Cynosure Aperture Lens 24 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Cynosure Elite+ handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672750464,"sku":"CYN-0053","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-common-aperture-lens-15-18-mm","title":"Cynosure Common Aperture Lens 15 \/ 18 mm","description":"\u003cp\u003e\u003cstrong\u003eCommon aperture lens for Cynosure Elite series handpieces, 15 mm and 18 mm sizes.\u003c\/strong\u003e Shared element that sits in the beam path for both spot configurations, shaping output ahead of the size-specific optics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Because every configuration passes through it, surface damage drags output down across all the spot sizes it serves at once, and the loss tracks every setting equally rather than pointing at one size.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672914304,"sku":"CYN-0054","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-common-aperture-lens-20-22-24-mm","title":"Cynosure Common Aperture Lens 20 \/ 22 \/ 24 mm","description":"\u003cp\u003e\u003cstrong\u003eCommon aperture lens for Cynosure Elite+ large spot handpieces, 20 mm, 22 mm, and 24 mm sizes.\u003c\/strong\u003e Shared element that sits in the beam path for all three configurations, shaping output ahead of the size-specific optics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Because every configuration passes through it, surface damage drags output down across all the spot sizes it serves at once, and the loss tracks every setting equally rather than pointing at one size.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673045376,"sku":"CYN-0055","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-elite-laser-head-cavity","title":"Cynosure Elite Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for Cynosure Elite series systems.\u003c\/strong\u003e Reflective chamber that holds the flash lamps, laser rod, and coolant flow tubes in fixed alignment, focusing pump light into the rod on every discharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rod and output falls below what calibration can recover. Damage compounds because the system drives the lamps harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673209216,"sku":"CYN-0016","price":1950.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-elite-plus-focus-lens","title":"Cynosure Elite+ Focus Lens","description":"\u003cp\u003e\u003cstrong\u003eFocus lens for the Cynosure Elite+ system.\u003c\/strong\u003e Precision element that converges the beam to its working focal point in the optical train, holding spot geometry and energy density at the design values on the dual wavelength platform.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage defocuses the beam at its target plane, spreading energy the system expects to be concentrated. Coupled energy drops, surrounding mounts absorb the difference as heat, and the delivered spot degrades.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673536896,"sku":"CYN-0057","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-elite-plus-laser-head-cavity","title":"Cynosure Elite+ Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for the Cynosure Elite+ system.\u003c\/strong\u003e Reflective chamber that holds the flash lamps, laser rods, and coolant flow tubes in fixed alignment for dual wavelength output on the 755 nm and 1064 nm platform.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rods and output falls below what calibration can recover. Damage compounds because the system drives the lamps harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673962880,"sku":"CYN-0015","price":1950.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-flash-lamp","title":"Cynosure Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Cynosure Elite series laser heads.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled head. Each discharge produces the broadband pulse that pumps the rod. Sold individually; each Elite series head runs two lamps, so order two for a full lamp change.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927676027264,"sku":"CYN-0031","price":165.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"quanta-system-duetto-flash-lamp","title":"Quanta System Duetto Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Quanta System Duetto laser systems.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927677600128,"sku":"DUT-0001","price":160.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"deka-synchro-replay-3-4-flash-lamp","title":"Deka Synchro Replay 3.4 Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Deka Synchro Replay 3.4 laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927678189952,"sku":"DEK-0003","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lumenis-splendor-x-flash-lamp","title":"Lumenis Splendor X Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp assembly for the Lumenis Splendor X laser system.\u003c\/strong\u003e Lamp assembly with a xenon-filled glass envelope, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm BLEND X platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927678714240,"sku":"SPX-0001","price":375.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"protective-window-lens","title":"Protective Window Lens","description":"\u003cp\u003e\u003cstrong\u003eDisposable protective window for laser handpieces.\u003c\/strong\u003e Flat optical window that sits in front of the internal lenses and takes the debris, gel, and hair contact of every treatment, so contamination lands on a replaceable part instead of the optics behind it.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Debris burned onto the surface absorbs pulse energy, etching the glass and turning the window from a shield into an absorber. Left in place, a marked window scatters energy, distorts the spot, and passes heat damage down the optical train.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927679435136,"sku":"WLD-0009","price":1.6,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"}],"url":"https:\/\/thephotonx.com\/collections\/low-output.oembed","provider":"ThePhotonX","version":"1.0","type":"link"}