{"title":"Laser Generation","description":"\u003cp\u003eThe parts that generate the beam inside the laser head: flash lamps, rods, cavities, reflectors, flow tubes, diode modules and CO2 tubes. Most are replaced as a set during a cavity rebuild.\u003c\/p\u003e","products":[{"product_id":"candela-flash-lamp","title":"Candela Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Candela Gentle series laser systems.\u003c\/strong\u003e Glass envelope with a xenon gas fill and ceramic end caps, mounted alongside the laser rod inside the water-cooled cavity. Each capacitor discharge fires the lamp, producing the intense broadband light pulse that pumps the rod and generates the treatment beam. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927659577728,"sku":"CND-0054","price":165.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0054.jpg?v=1789840379"},{"product_id":"candela-laser-head-cavity","title":"Candela Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for Candela Gentle series systems.\u003c\/strong\u003e Reflective chamber that holds the flash lamp, laser rod, and coolant flow tubes in fixed alignment, focusing the lamp's pump light into the rod on every discharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rod and output falls below what calibration can recover. Damage compounds because the system drives the lamp harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927667048832,"sku":"CND-0033","price":990.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0033.jpg?v=1792157083"},{"product_id":"lutronic-clarity-flash-lamp","title":"Lutronic Clarity Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Lutronic Clarity laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671144832,"sku":"CLR-0015","price":200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-ii-flash-lamp","title":"Lutronic Clarity II Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Lutronic Clarity II laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e\u003cp\u003eNot interchangeable with the original Clarity lamp; confirm the system version before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671439744,"sku":"CLR-0016","price":200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-elite-laser-head-cavity","title":"Cynosure Elite Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for Cynosure Elite series systems.\u003c\/strong\u003e Reflective chamber that holds the flash lamps, laser rod, and coolant flow tubes in fixed alignment, focusing pump light into the rod on every discharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rod and output falls below what calibration can recover. Damage compounds because the system drives the lamps harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673209216,"sku":"CYN-0016","price":1950.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-elite-plus-laser-head-cavity","title":"Cynosure Elite+ Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for the Cynosure Elite+ system.\u003c\/strong\u003e Reflective chamber that holds the flash lamps, laser rods, and coolant flow tubes in fixed alignment for dual wavelength output on the 755 nm and 1064 nm platform.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rods and output falls below what calibration can recover. Damage compounds because the system drives the lamps harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673962880,"sku":"CYN-0015","price":1950.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-flash-lamp","title":"Cynosure Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Cynosure Elite series laser heads.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled head. Each discharge produces the broadband pulse that pumps the rod. Sold individually; each Elite series head runs two lamps, so order two for a full lamp change.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927676027264,"sku":"CYN-0031","price":165.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"quanta-system-duetto-flash-lamp","title":"Quanta System Duetto Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Quanta System Duetto laser systems.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927677600128,"sku":"DUT-0001","price":160.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"deka-synchro-replay-3-4-flash-lamp","title":"Deka Synchro Replay 3.4 Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Deka Synchro Replay 3.4 laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927678189952,"sku":"DEK-0003","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lumenis-splendor-x-flash-lamp","title":"Lumenis Splendor X Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp assembly for the Lumenis Splendor X laser system.\u003c\/strong\u003e Lamp assembly with a xenon-filled glass envelope, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm BLEND X platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927678714240,"sku":"SPX-0001","price":375.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"}],"url":"https:\/\/thephotonx.com\/collections\/laser-generation.oembed","provider":"ThePhotonX","version":"1.0","type":"link"}