{"title":"Best Sellers","description":"\u003cp\u003eThe parts clinics and service engineers order most often across all supported brands. Stocked, factory tested, and ready to ship.\u003c\/p\u003e","products":[{"product_id":"candela-aperture-lens-18-mm","title":"Candela Aperture Lens 18 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle series handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to an 18 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927654007168,"sku":"CND-0077","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0077.jpg?v=1789840430"},{"product_id":"candela-aperture-lens-24-mm-type-1","title":"Candela Aperture Lens 24 mm (Type 1)","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle Pro series handpieces, 24 mm Type 1.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e\u003cp\u003eThree 24 mm lens types exist for this platform; confirm the fitted type against your slider before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927654465920,"sku":"CND-0078","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0078.jpg?v=1789840465"},{"product_id":"candela-aperture-lens-24-mm-type-2","title":"Candela Aperture Lens 24 mm (Type 2)","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle Pro series handpieces, 24 mm Type 2.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e\u003cp\u003eThree 24 mm lens types exist for this platform; confirm the fitted type against your slider before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927654990208,"sku":"CND-0079","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0079.jpg?v=1789839885"},{"product_id":"candela-aperture-lens-24-mm-type-3","title":"Candela Aperture Lens 24 mm (Type 3)","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Candela Gentle Pro series handpieces, 24 mm Type 3.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot inside the fiber slider, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e\u003cp\u003eThree 24 mm lens types exist for this platform; confirm the fitted type against your slider before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927655645568,"sku":"CND-0080","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0080.jpg?v=1789839868"},{"product_id":"candela-beam-combiner","title":"Candela Beam Combiner","description":"\u003cp\u003e\u003cstrong\u003eBeam combiner for Candela Gentle Pro series systems.\u003c\/strong\u003e Dichroic optic that merges the 755 nm and 1064 nm paths into a single output line in dual wavelength configurations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Coating damage attenuates or misaligns one wavelength's path more than the other, so the two outputs drift apart and a single calibration can no longer hold both wavelengths at spec.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927656071552,"sku":"CND-0084","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0084.jpg?v=1789840508"},{"product_id":"candela-beam-splitter","title":"Candela Beam Splitter","description":"\u003cp\u003e\u003cstrong\u003eBeam splitter for Candela Gentle Pro series systems.\u003c\/strong\u003e Partially reflective optic that divides the beam between paths at a fixed ratio, feeding the system the sample it uses to monitor output energy.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Coating degradation shifts the split ratio, so the sampled energy and the delivered energy drift apart. The system calibrates to the sample, which means real output at the skin walks away from the displayed value.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927656333696,"sku":"CND-0085","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0085.jpg?v=1789840578"},{"product_id":"candela-fiber-board-id-sensor-12-15-18-mm","title":"Candela Fiber Board (ID Sensor) 12 \/ 15 \/ 18 mm","description":"\u003cp\u003e\u003cstrong\u003eSpot size identification board for Candela fiber sliders in the 12 \/ 15 \/ 18 mm range.\u003c\/strong\u003e Sensor board that reads the slider's position at each detent and reports the fitted spot size to the system before it allows firing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Contact wear and trace damage corrupt the position signal, so the system misreads or fails to detect the fitted size and blocks treatment. A failed board takes the whole handpiece out of service until replaced.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927656628608,"sku":"CND-0051","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0051.jpg?v=1789840313"},{"product_id":"candela-fiber-board-id-sensor-20-22-24-mm","title":"Candela Fiber Board (ID Sensor) 20 \/ 22 \/ 24 mm","description":"\u003cp\u003e\u003cstrong\u003eSpot size identification board for Candela fiber sliders in the 20 \/ 22 \/ 24 mm range.\u003c\/strong\u003e Sensor board that reads the slider's position at each detent and reports the fitted spot size to the system before it allows firing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Contact wear and trace damage corrupt the position signal, so the system misreads or fails to detect the fitted size and blocks treatment. A failed board takes the whole handpiece out of service until replaced.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927657316736,"sku":"CND-0052","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0052.jpg?v=1789840331"},{"product_id":"candela-fiber-board-id-sensor-26-mm","title":"Candela Fiber Board (ID Sensor) 26 mm","description":"\u003cp\u003e\u003cstrong\u003eSpot size identification board for Candela fiber sliders in the 26 mm range.\u003c\/strong\u003e Sensor board that reads the slider's position at each detent and reports the fitted spot size to the system before it allows firing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Contact wear and trace damage corrupt the position signal, so the system misreads or fails to detect the fitted size and blocks treatment. A failed board takes the whole handpiece out of service until replaced.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927657611648,"sku":"CND-0053","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0053.jpg?v=1789840355"},{"product_id":"candela-fiber-slider-18-mm-no-lenses","title":"Candela Fiber Slider 18 mm (No Lenses)","description":"\u003cp\u003e\u003cstrong\u003eFiber slider assembly for Candela Gentle series handpieces, 18 mm spot size, supplied without lenses.\u003c\/strong\u003e Metal carrier that holds the spot size optics and indexes the fiber position into the selected aperture's detent.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Detent and latch wear let the slider drift or seat incompletely, so the size the system reads and the optics actually in the beam path can disagree. With a known good ID board, repeated misreads point at the slider itself.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927658004864,"sku":"CND-0128","price":85.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0128.jpg?v=1789842008"},{"product_id":"candela-fiber-slider-24-mm-no-lenses","title":"Candela Fiber Slider 24 mm (No Lenses)","description":"\u003cp\u003e\u003cstrong\u003eFiber slider assembly for Candela Gentle series handpieces, 24 mm spot size, supplied without lenses.\u003c\/strong\u003e Metal carrier that holds the spot size optics and indexes the fiber position into the selected aperture's detent.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Detent and latch wear let the slider drift or seat incompletely, so the size the system reads and the optics actually in the beam path can disagree. With a known good ID board, repeated misreads point at the slider itself.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927658856832,"sku":"CND-0129","price":85.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0129.jpg?v=1789842056"},{"product_id":"candela-fiber-slider-26-mm-no-lenses","title":"Candela Fiber Slider 26 mm (No Lenses)","description":"\u003cp\u003e\u003cstrong\u003eFiber slider assembly for Candela Gentle series handpieces, 26 mm spot size, supplied without lenses.\u003c\/strong\u003e Metal carrier that holds the spot size optics and indexes the fiber position into the selected aperture's detent.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Detent and latch wear let the slider drift or seat incompletely, so the size the system reads and the optics actually in the beam path can disagree. With a known good ID board, repeated misreads point at the slider itself.\u003c\/p\u003e\u003cp\u003eThe 26 mm assembly is specific to the large spot handpiece and is not interchangeable with smaller sliders.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927659282816,"sku":"CND-0130","price":85.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"candela-flash-lamp","title":"Candela Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for Candela Gentle series laser systems.\u003c\/strong\u003e Glass envelope with a xenon gas fill and ceramic end caps, mounted alongside the laser rod inside the water-cooled cavity. Each capacitor discharge fires the lamp, producing the intense broadband light pulse that pumps the rod and generates the treatment beam. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927659577728,"sku":"CND-0054","price":165.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0054.jpg?v=1789840379"},{"product_id":"candela-focus-lens","title":"Candela Focus Lens","description":"\u003cp\u003e\u003cstrong\u003eFocus lens for Candela Gentle Pro series systems.\u003c\/strong\u003e Precision element that converges the beam to its working focal point in the optical train, holding spot geometry and energy density at the design values.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage defocuses the beam at its target plane, spreading energy the system expects to be concentrated. Coupled energy drops, surrounding mounts absorb the difference as heat, and the delivered spot degrades.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927660396928,"sku":"CND-0086","price":60.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"candela-handpiece-air-cover-gentlemax-pro","title":"Candela Handpiece Air Cover GentleMax Pro","description":"\u003cp\u003e\u003cstrong\u003eHandpiece shell cover for Candela Gentle Pro series ACC air-cooled handpieces.\u003c\/strong\u003e Molded shell that carries the trigger and slider buttons and closes around the boards and optics inside the handpiece.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Cracks start at the fastener bosses and spread under normal grip pressure, opening paths for knocks and cleaning fluids to reach the electronics the shell exists to protect.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927660691840,"sku":"CND-0112","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0112.jpg?v=1789841252"},{"product_id":"candela-handpiece-air-cover-gentlemax-pro-plus","title":"Candela Handpiece Air Cover GentleMax Pro Plus","description":"\u003cp\u003e\u003cstrong\u003eHandpiece shell cover for Candela GentleMax Pro Plus ACC air-cooled handpieces.\u003c\/strong\u003e Molded shell that carries the trigger and slider buttons and closes around the boards and optics inside the handpiece.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Cracks start at the fastener bosses and spread under normal grip pressure, opening paths for knocks and cleaning fluids to reach the electronics the shell exists to protect.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927660953984,"sku":"CND-0114","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0114.jpg?v=1789841450"},{"product_id":"candela-handpiece-board-12-15-18-mm-air","title":"Candela Handpiece Board 12 \/ 15 \/ 18 mm Air","description":"\u003cp\u003e\u003cstrong\u003ePCB control board for Candela Gentle Pro series handpieces, 12 \/ 15 \/ 18 mm air-cooled configuration.\u003c\/strong\u003e The board reads trigger and slider inputs, times the air cooling valve against each pulse, and handles communication between the handpiece and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Heat cycling and connector wear degrade the board's traces and joints, producing dropped communication, mistimed cooling, and a handpiece that intermittently stops firing. Faults stay within this size group's board and do not carry across configurations.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927661248896,"sku":"CND-0671","price":195.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0671.jpg?v=1789840957"},{"product_id":"candela-handpiece-board-12-15-18-mm-dcd","title":"Candela Handpiece Board 12 \/ 15 \/ 18 mm DCD","description":"\u003cp\u003e\u003cstrong\u003ePCB control board for Candela Gentle Pro series handpieces, 12 \/ 15 \/ 18 mm DCD cryogen-cooled configuration.\u003c\/strong\u003e The board reads trigger and slider inputs, times the DCD cryogen spray against each pulse, and handles communication between the handpiece and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Heat cycling and connector wear degrade the board's traces and joints, producing dropped communication, mistimed cooling, and a handpiece that intermittently stops firing. Faults stay within this size group's board and do not carry across configurations.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927661609344,"sku":"CND-0672","price":195.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0672.jpg?v=1789840984"},{"product_id":"candela-handpiece-board-20-22-24-mm-air","title":"Candela Handpiece Board 20 \/ 22 \/ 24 mm Air","description":"\u003cp\u003e\u003cstrong\u003ePCB control board for Candela Gentle Pro series handpieces, 20 \/ 22 \/ 24 mm air-cooled configuration.\u003c\/strong\u003e The board reads trigger and slider inputs, times the air cooling valve against each pulse, and handles communication between the handpiece and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Heat cycling and connector wear degrade the board's traces and joints, producing dropped communication, mistimed cooling, and a handpiece that intermittently stops firing. Faults stay within this size group's board and do not carry across configurations.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927662330240,"sku":"CND-0673","price":195.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0673.jpg?v=1789841028"},{"product_id":"candela-handpiece-board-20-22-24-mm-dcd","title":"Candela Handpiece Board 20 \/ 22 \/ 24 mm DCD","description":"\u003cp\u003e\u003cstrong\u003ePCB control board for Candela Gentle Pro series handpieces, 20 \/ 22 \/ 24 mm DCD cryogen-cooled configuration.\u003c\/strong\u003e The board reads trigger and slider inputs, times the DCD cryogen spray against each pulse, and handles communication between the handpiece and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Heat cycling and connector wear degrade the board's traces and joints, producing dropped communication, mistimed cooling, and a handpiece that intermittently stops firing. Faults stay within this size group's board and do not carry across configurations.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927662887296,"sku":"CND-0674","price":195.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0674.jpg?v=1789841061"},{"product_id":"candela-handpiece-board-26-mm-air","title":"Candela Handpiece Board 26 mm Air","description":"\u003cp\u003e\u003cstrong\u003ePCB control board for Candela Gentle Pro series handpieces, 26 mm air-cooled configuration.\u003c\/strong\u003e The board reads trigger and slider inputs, times the air cooling valve against each pulse, and handles communication between the handpiece and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Heat cycling and connector wear degrade the board's traces and joints, producing dropped communication, mistimed cooling, and a handpiece that intermittently stops firing. Faults stay within this size group's board and do not carry across configurations.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927663608192,"sku":"CND-0675","price":195.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0675.jpg?v=1789841094"},{"product_id":"candela-handpiece-board-26-mm-dcd","title":"Candela Handpiece Board 26 mm DCD","description":"\u003cp\u003e\u003cstrong\u003ePCB control board for Candela Gentle Pro series handpieces, 26 mm DCD cryogen-cooled configuration.\u003c\/strong\u003e The board reads trigger and slider inputs, times the DCD cryogen spray against each pulse, and handles communication between the handpiece and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Heat cycling and connector wear degrade the board's traces and joints, producing dropped communication, mistimed cooling, and a handpiece that intermittently stops firing. Faults stay within this size group's board and do not carry across configurations.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927664034176,"sku":"CND-0676","price":195.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0676.jpg?v=1789841123"},{"product_id":"candela-handpiece-bubble-board","title":"Candela Handpiece Bubble Board","description":"\u003cp\u003e\u003cstrong\u003eBubble sensor board for Candela Gentle Pro series DCD handpieces.\u003c\/strong\u003e Sensor board that monitors the cryogen line for entrained air and halts DCD delivery the moment gas continuity is lost.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e A degraded sensor fails in one of two directions: it blocks cryogen delivery on a clean supply, or it stops detecting real bubbles and removes a patient safety protection. Either way the DCD circuit can no longer be trusted.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927664263552,"sku":"CND-0061","price":85.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"candela-handpiece-dcd-cover-gentlemax-pro","title":"Candela Handpiece DCD Cover GentleMax Pro","description":"\u003cp\u003e\u003cstrong\u003eHandpiece shell cover for Candela Gentle Pro series DCD cryogen-cooled handpieces.\u003c\/strong\u003e Molded shell that carries the trigger and slider buttons and closes around the boards, DCD valve, and optics inside the handpiece.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Cracks start at the fastener bosses and spread under normal grip pressure, opening paths for knocks and cleaning fluids to reach the electronics the shell exists to protect.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927664558464,"sku":"CND-0111","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0111-3.jpg?v=1789841898"},{"product_id":"candela-handpiece-dcd-cover-gentlemax-pro-plus","title":"Candela Handpiece DCD Cover GentleMax Pro Plus","description":"\u003cp\u003e\u003cstrong\u003eHandpiece shell cover for Candela GentleMax Pro Plus DCD cryogen-cooled handpieces.\u003c\/strong\u003e Molded shell that carries the trigger and slider buttons and closes around the boards, DCD valve, and optics inside the handpiece.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Cracks start at the fastener bosses and spread under normal grip pressure, opening paths for knocks and cleaning fluids to reach the electronics the shell exists to protect.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927664853376,"sku":"CND-0113","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0113.jpg?v=1789841862"},{"product_id":"candela-handpiece-slider-button","title":"Candela Handpiece Slider Button","description":"\u003cp\u003e\u003cstrong\u003eReplacement slider button for Candela Gentle Pro series handpieces.\u003c\/strong\u003e Molded release button that locks the fiber slider into each spot size detent and holds the selected aperture in position on the handpiece body during treatment.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Wear on the latch face lets the slider drift between detents under light pressure, so the spot size in the beam path can shift away from the size the system reports, changing delivered fluence without warning.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927665213824,"sku":"CND-0062","price":20.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0062.jpg?v=1789840408"},{"product_id":"candela-handpiece-trigger-button","title":"Candela Handpiece Trigger Button","description":"\u003cp\u003e\u003cstrong\u003eReplacement trigger button for Candela Gentle Pro series handpieces.\u003c\/strong\u003e Molded plastic button that seats in the handpiece shell and actuates the firing switch beneath it. The tactile click is the operator's physical confirmation that a pulse has been commanded.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Repeated actuation wears the button's pivot and contact face, so the click softens and switch travel becomes inconsistent. The operator loses confirmation of firing, and pulses can be missed or doubled at the treatment site.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927665508736,"sku":"CND-0065","price":19.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"candela-intermediate-lens","title":"Candela Intermediate Lens","description":"\u003cp\u003e\u003cstrong\u003eIntermediate lens for Candela Gentle Pro series systems.\u003c\/strong\u003e Relay element that keeps the beam collimated between stages of the optical train so the full aperture arrives at the next optic.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage lets the beam spread between stages, clipping energy at downstream apertures and softening the spot at the handpiece. Because the loss is distributed, it often reads as general low output rather than one failed optic.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927666196864,"sku":"CND-0087","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0087.jpg?v=1789840597"},{"product_id":"candela-laser-head-cavity","title":"Candela Laser Head Cavity","description":"\u003cp\u003e\u003cstrong\u003eLaser head cavity for Candela Gentle series systems.\u003c\/strong\u003e Reflective chamber that holds the flash lamp, laser rod, and coolant flow tubes in fixed alignment, focusing the lamp's pump light into the rod on every discharge.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Reflector coatings dull with age and coolant ingress etches the chamber, so less pump light reaches the rod and output falls below what calibration can recover. Damage compounds because the system drives the lamp harder to compensate.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927667048832,"sku":"CND-0033","price":990.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0033.jpg?v=1792157083"},{"product_id":"candela-pcb-wire-gentlemax-pro-9035","title":"Candela PCB Wire GentleMax Pro 9035","description":"\u003cp\u003e\u003cstrong\u003eSignal wire harness for Candela Gentle Pro series systems, reference 9035.\u003c\/strong\u003e Multi-conductor harness that carries handpiece signal and counter data between the handpiece board and the main system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Flex cycles fatigue the conductors at the connector crimps, producing intermittent faults that appear under movement and vanish on the bench. The failures mimic board faults and are frequently misdiagnosed.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927668818304,"sku":"CND-0018","price":30.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0018.jpg?v=1789840034"},{"product_id":"candela-pcb-wire-head-counter-alex","title":"Candela PCB Wire Head Counter Alex","description":"\u003cp\u003e\u003cstrong\u003eShot counter wire harness for the Alexandrite laser head in Candela Gentle Pro series systems.\u003c\/strong\u003e Dedicated harness that carries the Alexandrite head's shot count to the system, keeping lamp and head usage tracking accurate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e A fatigued harness stops the count advancing while the head keeps firing, so recorded usage falls behind real wear and lamp and cavity maintenance slips out of schedule.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927669113216,"sku":"CND-0017","price":30.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0017.jpg?v=1789840007"},{"product_id":"candela-pcb-wire-head-counter-yag","title":"Candela PCB Wire Head Counter YAG","description":"\u003cp\u003e\u003cstrong\u003eShot counter wire harness for the Nd:YAG laser head in Candela Gentle Pro series systems.\u003c\/strong\u003e Dedicated harness that carries the Nd:YAG head's shot count to the system, keeping lamp and head usage tracking accurate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e A fatigued harness stops the count advancing while the head keeps firing, so recorded usage falls behind real wear and lamp and cavity maintenance slips out of schedule.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927669408128,"sku":"CND-0019","price":30.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0019-2.jpg?v=1789840132"},{"product_id":"candela-shutter-support-frame","title":"Candela Shutter Support Frame","description":"\u003cp\u003e\u003cstrong\u003eMetal support frame for the shutter assembly in Candela Gentle Pro series systems.\u003c\/strong\u003e Rigid frame that holds the shutter mechanism square to the beam path, keeping the safety shutter's open and closed positions aligned with the aperture.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e A bent or cracked frame lets the shutter sit off axis, so it no longer fully clears or fully blocks the aperture. The system reads this as shutter faults, and partial blockage clips the beam and shows as uneven output.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927669604736,"sku":"CND-0123","price":175.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0123.jpg?v=1789840693"},{"product_id":"candela-turning-mirror","title":"Candela Turning Mirror","description":"\u003cp\u003e\u003cstrong\u003eTurning mirror for Candela Gentle Pro series systems.\u003c\/strong\u003e Coated mirror that folds the beam through the internal path at a fixed angle, keeping the line between rod and handpiece aligned within the housing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Coating burns and pitting scatter energy out of the folded path, cutting delivered fluence and heating the mount. Scatter also degrades beam shape by the time it reaches the handpiece, so losses show at the skin before they show on the bench.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927669801344,"sku":"CND-0088","price":100.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/CND-0088.jpg?v=1789840619"},{"product_id":"lutronic-clarity-air-adaptor","title":"Lutronic Clarity Air Adaptor","description":"\u003cp\u003e\u003cstrong\u003eAir cooling adaptor for the Lutronic Clarity handpiece.\u003c\/strong\u003e Molded coupling that locks a cold air hose to the handpiece nose and channels the airflow onto the treatment site while the beam fires.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Cracks and worn grip surfaces let the coupling bleed air before it reaches the skin, and a deformed nozzle scatters what remains away from the pulse site. Epidermal cooling weakens exactly where fluence is highest.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927669965184,"sku":"CLR-0003","price":600.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-aperture-lens-15-mm","title":"Lutronic Clarity Aperture Lens 15 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 15 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670129024,"sku":"CLR-0020","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-aperture-lens-18-mm","title":"Lutronic Clarity Aperture Lens 18 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 18 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670358400,"sku":"CLR-0021","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-aperture-lens-20-mm","title":"Lutronic Clarity Aperture Lens 20 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 20 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670587776,"sku":"CLR-0022","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-common-aperture-lens","title":"Lutronic Clarity Common Aperture Lens","description":"\u003cp\u003e\u003cstrong\u003eCommon aperture lens for the Lutronic Clarity platform.\u003c\/strong\u003e Shared element that sits in the beam path for every spot size configuration it serves, shaping output ahead of the size-specific optics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Because every configuration passes through it, surface damage drags output down across all the spot sizes it serves at once, and the loss tracks every setting equally rather than pointing at one size.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927670751616,"sku":"CLR-0023","price":45.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-flash-lamp","title":"Lutronic Clarity Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Lutronic Clarity laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod on the 755 nm and 1064 nm platform. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671144832,"sku":"CLR-0015","price":200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-focus-lens","title":"Lutronic Clarity Focus Lens","description":"\u003cp\u003e\u003cstrong\u003eFocus lens for the Lutronic Clarity handpiece.\u003c\/strong\u003e Precision element that converges the beam to its working focal point for treatment delivery, holding spot geometry and energy density at the design values.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Surface damage defocuses the beam at its target plane, spreading energy the system expects to be concentrated. Coupled energy drops, surrounding mounts absorb the difference as heat, and the delivered spot degrades.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671275904,"sku":"CLR-0024","price":75.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-ii-flash-lamp","title":"Lutronic Clarity II Flash Lamp","description":"\u003cp\u003e\u003cstrong\u003eXenon flash lamp for the Lutronic Clarity II laser system.\u003c\/strong\u003e Glass envelope with a xenon gas fill, mounted alongside the laser rod inside the water-cooled cavity. Each discharge produces the broadband pulse that pumps the rod. Sold individually.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Every discharge erodes the electrodes and degrades the gas fill, so the lamp delivers less pump light for the same input energy. The system compensates by raising drive energy until calibration reaches its limit, and a worn lamp left running accelerates damage to the cavity reflectors around it.\u003c\/p\u003e\u003cp\u003eNot interchangeable with the original Clarity lamp; confirm the system version before ordering.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671439744,"sku":"CLR-0016","price":200.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"lutronic-clarity-protective-window","title":"Lutronic Clarity Protective Window","description":"\u003cp\u003e\u003cstrong\u003eDisposable protective window for the Lutronic Clarity handpiece.\u003c\/strong\u003e Flat optical window that sits in front of the internal lenses and takes the debris, gel, and hair contact of every treatment, so contamination lands on a replaceable part instead of the optics behind it. Sold per piece.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Debris burned onto the surface absorbs pulse energy, etching the glass and turning the window from a shield into an absorber. Left in place, a marked window scatters energy, distorts the spot, and passes heat damage down the optical train.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927671996800,"sku":"CLR-0025","price":10.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-air-adaptor","title":"Cynosure Air Adaptor","description":"\u003cp\u003e\u003cstrong\u003eAir cooling adaptor for Cynosure Elite series handpieces.\u003c\/strong\u003e Molded coupling that locks a cold air hose to the handpiece nose and channels the airflow onto the treatment site while the beam fires.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Cracks and worn grip surfaces let the coupling bleed air before it reaches the skin, and a deformed nozzle scatters what remains away from the pulse site. Epidermal cooling weakens exactly where fluence is highest.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672160640,"sku":"CYN-0005","price":110.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-18-mm","title":"Cynosure Aperture Lens 18 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for Cynosure Elite series handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 18 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672324480,"sku":"CYN-0050","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-20-mm","title":"Cynosure Aperture Lens 20 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Cynosure Elite+ handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 20 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672488320,"sku":"CYN-0051","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-22-mm","title":"Cynosure Aperture Lens 22 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Cynosure Elite+ handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 22 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672553856,"sku":"CYN-0052","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-aperture-lens-24-mm","title":"Cynosure Aperture Lens 24 mm","description":"\u003cp\u003e\u003cstrong\u003eOptical aperture lens for the Cynosure Elite+ handpieces.\u003c\/strong\u003e Precision-ground element that shapes the beam to a 24 mm treatment spot, setting the fluence profile delivered at the skin.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Scratches, pits, and burn marks scatter energy unevenly across the spot, so parts of the treatment area run hot while others fall short. Damage cannot be polished out without changing the lens geometry, so the element is replaced as a unit.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672750464,"sku":"CYN-0053","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-common-aperture-lens-15-18-mm","title":"Cynosure Common Aperture Lens 15 \/ 18 mm","description":"\u003cp\u003e\u003cstrong\u003eCommon aperture lens for Cynosure Elite series handpieces, 15 mm and 18 mm sizes.\u003c\/strong\u003e Shared element that sits in the beam path for both spot configurations, shaping output ahead of the size-specific optics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Because every configuration passes through it, surface damage drags output down across all the spot sizes it serves at once, and the loss tracks every setting equally rather than pointing at one size.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927672914304,"sku":"CYN-0054","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"},{"product_id":"cynosure-common-aperture-lens-20-22-24-mm","title":"Cynosure Common Aperture Lens 20 \/ 22 \/ 24 mm","description":"\u003cp\u003e\u003cstrong\u003eCommon aperture lens for Cynosure Elite+ large spot handpieces, 20 mm, 22 mm, and 24 mm sizes.\u003c\/strong\u003e Shared element that sits in the beam path for all three configurations, shaping output ahead of the size-specific optics.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy it fails:\u003c\/strong\u003e Because every configuration passes through it, surface damage drags output down across all the spot sizes it serves at once, and the loss tracks every setting equally rather than pointing at one size.\u003c\/p\u003e","brand":"PhotonX","offers":[{"title":"Default Title","offer_id":59927673045376,"sku":"CYN-0055","price":35.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0995\/9948\/3264\/files\/Product_Image_Placeholder.webp?v=1789852963"}],"url":"https:\/\/thephotonx.com\/collections\/best-sellers.oembed","provider":"ThePhotonX","version":"1.0","type":"link"}